  • ETC Response RSN-LV R3 Gateway
  • ETC Response RSN-LV R3 Gateway diagram
$716.00
Frequently bought together:

Description

The ETC Response 0-10V Gateway accepts streaming ACN (sACN) and DMX control input to provide 24 outputs of 0–10 V control. It is ideal for both retrofit and new power control system installations that require four-wire LED drivers and fluorescent ballasts. The gateway also accepts a contact input to set each channel’s output to a programmed level for use in UL 924 emergency lighting applications with UL 924 Listed Directly Controlled Emergency Luminaires (DCEL).

Configuration of the 0-10V Gateway is simple with ETC’s Concert software for remote management or via the onboard four-button interface. Users can build their own custom dimming curve or take advantage of a pre-programmed curve in the Gateway’s library. The Gateway can be mounted anywhere standard DIN rail is installed. And ETC's variety of DIN rail enclosures ensure you have a secure, convenient place to house your DIN rail devices.

FEATURES

  • Supports 24 0-10V control outputs, each supporting voltage sink connections up to 400mA maximum current per output
  • 18-24VDC power input
  • Supports streaming ACN (sACN) or DMX control input
  • UL924 listed for use in emergency systems
  • Remotely configurable via Concert

SPECIFICATIONS

FUNCTIONAL

  • Supports sACN control input (ANSI E1.31)
  • Supports USITT DMX512-A control input (ANSI E1.11)
  • Supports 0–10 V sink control (IEC60929 Annex E)
  • Supports per-address- or per-universe sACN priority
  • Configurable dimming curve per channel
    • Linear
    • Mod-Square
    • Custom

MECHANICAL

  • Intuitive four-button interface
  • Onboard display for identification, status, and configuration
  • Extruded aluminum enclosure
  • Network, power, and emergency activity indicators:
    • Blue power indicator
    • Green and yellow network activity indicator
    • Red emergency indicator
  • RJ45 receptacle for connection to lighting network
  • Pluggable terminals provided for all wiring connections
  • Selection switch for emergency input configuration: Normally Open, Normally Closed, or Off
  •  Local Push To Test button for emergency input
  • Selection switch for DMX input termination
  • 14 unit DIN enclosure width
  • Mounting complies with DIN43880 (35/7.5 rail)

ENVIRONMENTAL

  • Ambient operating temperature: 0°C to 40°C (32°F to 104°F)
  • Operating humidity: 5%–95% non-condensing
  • Storage temperature: -40°C to 70°C (-40°F to 158°F)

ELECTRICAL

  • Compliant with IEEE 802.3i for 10BASE-T, 802.3u for 100BASE-TX and 802.3af for Power over Ethernet (PoE)
  • IEEE 802.3af, Type 1, PD class 2 PoE input for non-emergency systems
  • 12–24 VDC power input using three-pin pluggable connection for use with non-PoE systems
  • Maximum 1 Amp current draw at 12–24 VDC
  • 24 0–10 V outputs, each supporting voltage sink connections, 100 mA maximum current per output

DMX INPUT PORT

  • Optically-isolated input from the gateway electronics
  • Withstands fault voltages of up to 250 VAC
  • Integrated DMX/RDM termination selection switch

CONFIGURATION

  • Onboard configuration using intuitive four-button interface
  • Configuration provided using Concert software
  • Configurable starting address
  • Configurable inclusion in emergency behavior
  • Up to four sources may be combined to the network with each source or address allowed an independent priority

PHYSICAL

  • Dimensions: 4.13 x 9.41 x 1.22 in. (105 x 239 x 31 mm)
  • Weight: 1.38 lbs (0.62 kg)
  • Shipping Weight: 2.63 lbs (1.19 kg)

REGULATORY AND COMPLIANCE

  • cETLus Listed
  • CE compliant
  • UKCA compliant
  • RoHS compliant
  • WEEE
  • UL 924 Listed for emergency lighting applications using UL 924 Listed Directly Controlled Emergency Luminaires (DCELs)